Validated in FTL FlowSuiteCompared with: Ansys Fluent
Shell-and-tube heat exchanger
Pressure drop (ΔP) and thermal performance (LMTD) of a shell-and-tube heat exchanger are analysed with conjugate heat transfer, with shell-side and tube-side water exchanging heat across the tube bundle. Flow and thermal fields are cross-validated between Ansys Fluent and FTL FlowSuite for mass flow rates of 0.5 to 2.5 kg/s on each side.
- Shell-and-tube heat exchanger
- Pressure drop
- LMTD
- Conjugate heat transfer
- 2.2%average deviation in LMTD
- 3%average deviation in pressure drop
- 0.5–2.5 kg/sflow rates tested
01 · Set-up
Model, mesh and settings
Simulation set-up
| Shell inlet | 0.5–2.5 kg/s, 293 K |
|---|---|
| Tube inlet | 0.5–2.5 kg/s, 313 K |
| Outlet | 1 bar |
| Mesh | 0.5 million cells |
| Fluid | Water (shell and tube side) |
| Turbulence inlet | Intensity and hydraulic diameter |
| Turbulence model | SST k-ω |
02 · Results
What the comparison shows
Highlights
- Both solvers agree closely in shell-side LMTD (about 2.2% average deviation) and pressure drop (about 3% average deviation) at every flow rate tested.
- Velocity and temperature fields match closely between the two solvers, confirming consistent thermal and hydraulic predictions.