Home » Case Studies » Pintle injector spray atomisation
Validated in FTL FlowSuiteCompared with: Son et al. (2016) · Radhakrishnan et al. (2018)
Pintle injector spray atomisation
A movable pintle injector forms a thin liquid sheet that is torn apart by a coaxial gas annulus. The spray is analysed with FTL FlowSuite's VOF-to-Lagrangian atomisation pipeline. Spray half-angle, Sauter mean diameter and spray density distribution are benchmarked against Son et al. (2016), with sheet-thickness data from Radhakrishnan et al. (2018).
- Pintle injector
- Spray half-angle
- VOF-to-Lagrangian
- Sauter mean diameter
- 50.2°spray half-angle from FlowSuite
- 58.1°measured (Son et al., 2016)
- 100.2 µmconverged SMD
01 · Set-up
Model, mesh and settings
Models
| Multiphase model | VOF-to-Lagrangian (VOF and Lagrangian breakup) |
|---|---|
| Breakup model | Reitz–Diwakar |
| Turbulence model | SST k-ω |
| Mesh | Adaptive mesh refinement |
02 · Results
What the comparison shows
Highlights
- FlowSuite predicts a spray half-angle of 50.2° for the 0.6 mm opening, 13.75% below the 58.1° measured by Son et al. (2016).
- The Sauter mean diameter converges to 100.2 µm, close to the 108–197 µm range reported for comparable pintle injectors (Radhakrishnan et al., 2018).