FlowThermoLab
Validated in FTL FlowSuiteCompared with: Son et al. (2016) · Radhakrishnan et al. (2018)

Pintle injector spray atomisation

A movable pintle injector forms a thin liquid sheet that is torn apart by a coaxial gas annulus. The spray is analysed with FTL FlowSuite's VOF-to-Lagrangian atomisation pipeline. Spray half-angle, Sauter mean diameter and spray density distribution are benchmarked against Son et al. (2016), with sheet-thickness data from Radhakrishnan et al. (2018).

  • Pintle injector
  • Spray half-angle
  • VOF-to-Lagrangian
  • Sauter mean diameter
Predicted hollow-cone spray from the pintle injector
  • 50.2°spray half-angle from FlowSuite
  • 58.1°measured (Son et al., 2016)
  • 100.2 µmconverged SMD
01 · Set-up

Model, mesh and settings

Models

Multiphase modelVOF-to-Lagrangian (VOF and Lagrangian breakup)
Breakup modelReitz–Diwakar
Turbulence modelSST k-ω
MeshAdaptive mesh refinement
Computational domain with boundary conditions
Liquid sheet breaking up into droplets
02 · Results

What the comparison shows

Highlights

  • FlowSuite predicts a spray half-angle of 50.2° for the 0.6 mm opening, 13.75% below the 58.1° measured by Son et al. (2016).
  • The Sauter mean diameter converges to 100.2 µm, close to the 108–197 µm range reported for comparable pintle injectors (Radhakrishnan et al., 2018).
Spray half-angle and spray density distribution
Droplet size distribution and running SMD, converged