Home » Case Studies » Air-cooled pin-fin heat sink
Validated in FTL FlowSuiteCompared with: Ansys Fluent
Air-cooled pin-fin heat sink
Forced-air cooling of a 10 W CPU through a pin-fin heat sink is analysed as conjugate heat transfer between the air, the heat sink and the board. Heat transfer coefficient, Nusselt number and temperature along a monitor line are cross-validated between Ansys Fluent and FTL FlowSuite.
- Pin-fin heat sink
- Conjugate heat transfer
- Forced-air convection
- Electronics cooling
- ~6%difference in heat transfer coefficient
- ~13%difference in Nusselt number
- 1.8 Mcells
01 · Set-up
Model, mesh and settings
Simulation set-up
| Inlet | 1 m/s |
|---|---|
| Outlet | 1 bar |
| Mesh | 1.8 million cells |
| Fluid | Air |
| Turbulence model | SST k-ω |
02 · Results
What the comparison shows
Highlights
- FlowSuite tracks Ansys Fluent within a small margin: about 6% in heat transfer coefficient and about 13% in Nusselt number.