FlowThermoLab
Validated in FTL FlowSuiteCompared with: Ansys Fluent

Air-cooled pin-fin heat sink

Forced-air cooling of a 10 W CPU through a pin-fin heat sink is analysed as conjugate heat transfer between the air, the heat sink and the board. Heat transfer coefficient, Nusselt number and temperature along a monitor line are cross-validated between Ansys Fluent and FTL FlowSuite.

  • Pin-fin heat sink
  • Conjugate heat transfer
  • Forced-air convection
  • Electronics cooling
Chip and board temperature, and temperature along the monitor line: Ansys Fluent vs FlowSuite
  • ~6%difference in heat transfer coefficient
  • ~13%difference in Nusselt number
  • 1.8 Mcells
01 · Set-up

Model, mesh and settings

Simulation set-up

Inlet1 m/s
Outlet1 bar
Mesh1.8 million cells
FluidAir
Turbulence modelSST k-ω
Pin-fin heat sink on a board with a 10 W CPU
Computational domain and boundary conditions
FlowSuite mesh
02 · Results

What the comparison shows

Highlights

  • FlowSuite tracks Ansys Fluent within a small margin: about 6% in heat transfer coefficient and about 13% in Nusselt number.
Average heat transfer coefficient at the chip: Ansys Fluent vs FlowSuite
Velocity in the centre plane: Ansys Fluent vs FlowSuite