FlowThermoLab
Validated in FTL FlowSuiteCompared with: Correlation of Lee et al. (2007)

Atomisation of a liquid jet in crossflow

A turbulent liquid jet injected into a gaseous crossflow is analysed with FTL FlowSuite's VOF-to-Lagrangian atomisation pipeline. The predicted Sauter mean diameter (SMD) at a fixed downstream sampling plane is benchmarked against the empirical correlation of Lee, Aalburg, Diez, Faeth and Sallam (2007).

  • Jet in crossflow
  • VOF-to-Lagrangian
  • Sauter mean diameter
  • Atomisation
VOF liquid column and Lagrangian droplet cloud after breakup
  • 212.0 µmSMD from FlowSuite
  • 220.5 µmSMD from Lee et al. (2007)
  • 3.9%deviation
01 · Set-up

Model, mesh and settings

Simulation set-up

Crossflow inlet velocity61.24 m/s (air)
Liquid nozzle inlet velocity13 m/s (water)
Outlet1 bar
Mesh600,000 initial cells with adaptive mesh refinement
Primary phaseWater
Turbulence modelSST k-ω
Multiphase modelVOF-to-Lagrangian (VOF and Lagrangian breakup)
Breakup modelReitz–Diwakar
Computational domain with boundary conditions
Structured duct mesh with near-wall clustering
Background mesh with adaptive refinement tracking the liquid jet
02 · Results

What the comparison shows

Highlights

  • FlowSuite predicts an SMD of 212.0 µm against 220.5 µm from Lee et al. (2007), a deviation of 3.9%.
  • A converged validation of FlowSuite's VOF-to-Lagrangian atomisation pipeline for jet breakup in crossflow.
050100150200250SMD (µm)220.5Lee et al. (2007)212.0FTL FlowSuite
Sauter mean diameter (µm). Data from this study.
Droplet diameter distribution at the sampling plane and predicted SMD