FlowThermoLab
Validated in FTL FlowSuiteCompared with: Ansys Fluent

GPU chip cooling

Chip, board and air conjugate heat transfer (CHT) is analysed for a 20 W GPU on a populated PCB, cooled by a fan-driven finned heat sink. The fan is modelled with an MRF (moving reference frame) rotating zone. Flow and thermal fields are cross-validated between Ansys Fluent and FTL FlowSuite.

  • Conjugate heat transfer
  • MRF fan
  • GPU
  • PCB cooling
Velocity and temperature: Ansys Fluent vs FlowSuite
  • 20 WGPU heat load
  • 1,500 rpmMRF fan zone
  • 1.8 Mcells
01 · Set-up

Model, mesh and settings

Simulation set-up

Fan (MRF zone)1,500 rpm
Outlet1 bar
Mesh1.8 million cells
FluidAir
Turbulence modelSST k-ω
The GPU card modelled
Computational domain with the MRF fan zone
02 · Results

What the comparison shows

Highlights

  • FlowSuite closely matches Ansys Fluent in predicting chip-surface temperature.
  • Flow structure across the MRF fan zone is consistent between the two solvers, with comparable velocity and temperature fields at the chip and heat sink.
Temperature comparison: Ansys Fluent vs FlowSuite