The notchback variant of the DrivAer reference car is used to validate FTL FlowSuite against wind-tunnel data. A 1:4 scale model is simulated in a computational domain sized in line with published benchmark studies. The drag coefficient (Cd) is cross-validated between Ansys Fluent and FTL FlowSuite, with both compared against the experimental measurement.

  • External aerodynamics
  • Wind tunnel
  • Drag coefficient
  • DrivAer
Predicted velocity field around the DrivAer notchback model
  • 0.26Cd from FlowSuite, matching experiment
  • 0.27Cd from Ansys Fluent
  • 18%shorter run time than Fluent
01 · Set-up

Model, mesh and settings

Simulation set-up

Inlet velocity30 m/s
Outlet pressure0 Pa (gauge)
Reference pressure101,325 Pa
Mesh600,000 cells
FluidAir
Viscosity1.7894 × 10⁻⁵ kg/(m·s)
Turbulence modelSST k-ω
DrivAer notchback model at 1:4 scale
Computational domain with boundary conditions
FlowSuite mesh around the car
Mesh refinement around the car body
02 · Results

What the comparison shows

Highlights

  • FlowSuite and Ansys Fluent give comparable aerodynamic predictions. FlowSuite predicts Cd = 0.26, matching the experimental value of 0.26.
  • FlowSuite completed the run about 18% faster than Ansys Fluent (3,127 s vs 3,800 s) with comparable results.
00.060.120.180.240.3Cd0.26Experiment0.27Ansys Fluent0.26FTL FlowSuite