FlowThermoLab
Validated in FTL FlowSuiteCompared with: Experiment (Foeth, 2008) · Ansys Fluent

Cavitation on the Delft twisted hydrofoil

Cavitation on the Delft twisted hydrofoil is analysed with VOF-URANS and Reboud's correction for turbulent viscosity, using adaptive mesh refinement (AMR) to resolve the vapour cavity interface. Lift coefficient and cavity shape are cross-validated between Ansys Fluent and FTL FlowSuite, and benchmarked against the experiments of Foeth (2008).

  • Cavitation
  • VOF-URANS
  • Reboud's correction
  • Adaptive mesh refinement
Cavitation cloud on the twisted hydrofoil
  • 0.4918CL from FlowSuite
  • 0.4943CL from Ansys Fluent
  • 0.4477CL measured (Foeth, 2008)
01 · Set-up

Model, mesh and settings

Simulation set-up

Inlet velocity6.97 m/s
Outlet pressure29,000 Pa
Angle of attack2°
Mesh800,000 initial cells with adaptive mesh refinement
Primary phaseWater
Turbulence modelSST k-ω
Multiphase modelVolume of fluid (VOF)
Cavitation modelSchnerr–Sauer with Reboud's correction
Computational domain with boundary conditions
FlowSuite mesh around the hydrofoil
Adaptive mesh refinement around the hydrofoil
02 · Results

What the comparison shows

Highlights

  • FlowSuite predicts CL = 0.4918 (+9.9%), closely matching Ansys Fluent's 0.4943 (+10.4%), against the experimental value of 0.4477 (Foeth, 2008).
  • Adaptive mesh refinement in FlowSuite resolves the cavity interface well, giving a larger and more accurate cavity shape.
00.120.240.360.480.6CL0.4477Experiment0.4943Ansys Fluent0.4918FTL FlowSuite
Lift coefficient. Data from this study.
Predicted cavity shape on the hydrofoil