FlowThermoLab
Validated in FTL FlowSuiteCompared with: Ansys CFX

Aachen 1.5-stage axial turbine

The Aachen turbine is a well-documented 1.5-stage cold-air axial turbine built and tested at the Institute of Jet Propulsion and Turbomachinery (IST), RWTH Aachen. With extensive measurements and a widely cited literature, it is a standard validation case for turbomachinery CFD. This study models the turbine with a structured multi-domain mesh and compares predicted performance from Ansys CFX and FTL FlowSuite.

  • Axial turbine
  • Turbomachinery
  • Structured mesh
  • Mixing plane
Predicted velocity through the 1.5 stages
  • 1.5stages: stator, rotor, stator
  • 5operating points, 1.20–1.58 bar
  • 3,500 rpmrotor speed
01 · Set-up

Model, mesh and settings

Simulation set-up

Inlet total pressure1.20, 1.30, 1.40, 1.50, 1.58 bar
Outlet static pressure1.00 bar
Inlet total temperature308 K
Rotor speed3,500 rpm
Mesh322,220 cells, sector model
FluidAir
Turbulence modelSST k-ω
Interface modelMixing plane (stage)
Computational domain with boundary conditions
FlowSuite structured mesh
02 · Results

What the comparison shows

Highlights

  • FlowSuite closely matches Ansys CFX in predicting rotor power across the operating conditions tested.
  • FlowSuite captures the pressure distribution and flow through all 1.5 stages, demonstrating its capability for turbomachinery simulation.
Rotor power vs total mass flow: Ansys CFX vs FlowSuite
Pressure at 10%, 50% and 90% span: Ansys CFX vs FlowSuite